尊龙凯时

Close
010-57374441
Support & Services

Troubleshooting for Hydraulic Pelletizing Press

Time : 2022-07-28 Visits : 537

The table below illustrates common causes for disruption in performance and is provided to assist the user in minimizing down time and to improve communications with our service personnel in diagnosing a problem.

Table3  Problems and solutions

Symptom

Possible cause

Corrective measure

Oil leak

Unit was tilted in transit

Overfilled reservoir

Loose hydraulic fittings

Loose lock ring in ram block

Worn ram O ring seals

Stabilize; clean up spill

Remove excess

Tighten

Tighten

Loss of pressure

Loss of hydraulic oil

Hydraulic oil leak; check fittings and seals to determine source

Defective hydraulic pump

Replenish with item 46#

Tighten fittings

 

Hydraulic pump inoperative

Disconnected wire/connector

Defective relay

Defective hydraulic pump

Reconnect

Ram does not move but pump is operative

Worn ram O ring seals

Contact customer support

Ram travels to maximum height but pump does not disengage

Defective proximity switch

Contact customer support

Ram travels to maximum down position but pump does not disengage

Ram remains stationary in one position with all other functions working properly

Defective proximity switch

 

Hydraulic oil bypassing ram O rings and wiper ring in the lower block assembly

Contact customer support


 

Contact customer support

 


PREV : Factors of Grinding Ball Wear of Planetary Grinding MillNEXT : Hardness of Grinding Ball Material Affects Final Grinding Results
网站地图网站地图
友情链接:银娱  尊龙凯时  尊龙凯时  米乐M6  suncitygroup  尊龙凯时  pg电子  腾博会官网  yp街机  乐虎国际lehu  尊龙凯时  bti体育